citrix systems office

Multi-Use, Office, Parking Deck | Solar, Smart Building, LEED Gold

Raleigh, NC

189,000 SF Office | 210,900 SF Parking Deck

$45 Million
Picture
Crenshaw Consulting Engineers Provided the Following Engineering Designs:
  • Plumbing
  • Mechanical
  • Electrical
  • Fire Alarm
  • Photovoltaic
Project Details:
​
  • Redevelopment of the 1915 Dillon Supply Warehouse into a state of the art smart office 
  • 4 Stories Office | 189,500 SF 
  • 7 Stories Parking | 210,900 SF
  • Retail on Ground Floor
  • Downtown Raleigh Campus
  • Building Automation Systems
  • Parking Deck & Pedestrian Bridge
  • Restaurant
  • Yoga Studio & Bocce
  • Fitness Center
  • Site Lighting
  • LED Lighting & Day Light Harvesting
  • 4 Pipe/Hot Chilled Water VAV (550 Ton)
  • Energy Modeling
  • Variable Flow Split with Energy Recovery
  • Solar/Hot Water Solar
  • ​Photovoltaics
  • 1.5 MW Full Building 24/7 Generator
  • Shell & Fit Up​

This project is the redevelopment of the abandoned 1915 Dillon Supply Warehouse into a state of the art office work space to include the addition of 2 floors as well as a Multi-Use Parking Deck and Complex.
​
Crenshaw Consulting Engineers provided the Plumbing, Mechanical, and Electrical, Fire Alarm Engineering Designs to include a 4 pipe hot and chilled water VAV mechanical system with a 550 ton cooling capacity as well as a variable refrigerant flow split conditioning system and energy recovery ventilation.  Other features include the design for a 1.5 megawatt generator with a UL 2085 and a 2,300 gallon diesel tank, hot water solar thermal consisting of 2,120 gallon storage tanks and 7 solar roof top panels providing 30% of the buildings hot water needs, day light harvesting, full building lighting control automation as well as an 11 kw photo voltaic solar system.  Numerous energy models were provided to determine the most cost efficient cutting edge energy savings methods and solutions.
Powered by Create your own unique website with customizable templates.
  • Home
  • Services
  • Projects
    • LEED | Sustainable | Smart
    • Solar and Renewable Energy Design
    • Office | Multi-Use
    • Multi-Family
    • Hotel | Resort | Spa
    • Data Centers
    • Financial
    • Medical
    • Dental
    • Assisted Living
    • Life Science | Laboratory
    • Education
    • Daycare & Preschool
    • Religious
    • Retail
    • Restaurant
    • Military
    • Government | Municipalities
    • Historic
    • Auto Dealerships | Auto Repair
    • Warehouse | Manufacturing | Flex Space
    • Storage Facilities
    • Recreational Fitness
  • About
    • People
  • Careers
  • Contact