Replace Medical Clinic - Project #71325

Medical, Military | LEED Silver

Seymour Johnson Air Force Base, NC

106,000 SF

$45.8 Million

Picture
Crenshaw Consulting Engineers Provided the Following Engineering Designs:
  • Plumbing
  • Mechanical
  • Electrical
Project Details:
​
  • ​The existing Main Clinic Building #2800 is a 98,000 SF single story structure that was originally built in 1957 and was comprised of approximately 36,200 SF with a later addition in 1975, as well as two much smaller additions in 1988 and 1995
  • The primary objective of this project was to replace the dated clinic with a new two story, 106,000 SF state-of-the-art primary care clinic
  • ​The New Clinic Includes:
    • ​Family Health
    • Physical Therapy
    • Pediatrics
    • Public Health
    • Women’s Health
    • Pharmacy
    • Flight Medicine
    • Mental Health
    • Optometry
    • Clinical Lab
  • LEED Silver under the 2009 LEED Healthcare Program
  • The HVAC System is Comprised of:
    • 3 Natural Gas Fired Condensing Boilers
    • 2  Air Cooled Screw Chillers
    • 4 VAV Double Wall Air Handling Units
    • Floor Mounted Radiant Fin tube Heaters
  • The Electrical System is Comprised of:
    • Estimated Size at 3,000 amps
    • Dedicated Panels for Type of Loads They Serve
    • Lighting Controls
  • The Mechanical, Plumbing, Electrical and Fire Alarm Systems were Designed to Meet the Requirements of a 30% Improvement over the ASHRAE 90.1-2007
  • The Building Includes a Vegetated Roof System and Translucent PTFE Canopy
Powered by Create your own unique website with customizable templates.
  • Home
  • Services
  • Projects
    • LEED | Sustainable | Smart
    • Solar and Renewable Energy Design
    • Office | Multi-Use
    • Multi-Family
    • Hotel | Resort | Spa
    • Data Centers
    • Financial
    • Medical
    • Dental
    • Assisted Living
    • Life Science | Laboratory
    • Education
    • Daycare & Preschool
    • Religious
    • Retail
    • Restaurant
    • Military
    • Government | Municipalities
    • Historic
    • Auto Dealerships | Auto Repair
    • Warehouse | Manufacturing | Flex Space
    • Storage Facilities
    • Recreational Fitness
  • About
    • People
  • Careers
  • Contact